AQA GCSE Combined Science: Trilogy Physics Paper 1 (Foundation), November 2020: Question 5

9 marks · Standard Demand difficulty · Short Answer

Identify plug wiring errors, state UK mains values, draw a fuse symbol, and explain the safety role of an earth wire.

Practise this question

Question

Question 5 contains a diagram (Figure 5) showing an incorrectly wired three-pin plug, where the blue wire goes to the top earth pin, the green and yellow wire goes to the left neutral pin, and the brown wire is correctly connected to the live pin via a fuse. Sub-questions ask: 05.1: What should be done to connect the wires correctly? (1 mark). 05.2: Give the potential difference and frequency of the UK mains supply (2 marks). 05.3: What is the potential difference between the neutral wire and the earth wire when switched on? (1 mark). 05.4: Draw the circuit symbol for a fuse (1 mark). 05.5: Explain why it is not safe to touch the metal case of a washing machine with a live wire fault if the earth wire is not connected (2 marks). 05.6: Explain why it would be safe to touch the metal case once the earth wire is connected (2 marks).
Question text

05 Figure 5 shows the inside of a plug.

Figure 5

05.1 The plug is not wired correctly.

What should be done to connect the wires in the plug correctly?

[1 mark]

The correctly wired plug and cable connects a washing machine to the mains

electricity supply.

05.2 Give the potential difference and frequency of the mains electricity supply in the UK.

[2 marks]

The potential difference is V

The frequency is Hz

05.3 The washing machine is switched on.

What is the potential difference between the neutral wire and the earth wire?

[1 mark]

Potential difference = V

05.4 The plug has a fuse.

Draw the circuit symbol for a fuse in the space below.20

*18* [1 mark]

The washing machine has a metal case.

A fault causes the live wire to make an electrical connection with the metal case of the

washing machine.

05.5 The earth wire is not connected to the metal case of the washing machine.

Explain why it would not be safe for a person to touch the metal case.

[2 marks]

05.6 The earth wire is now connected to the metal case of the washing machine.

*19* Explain why it would now be safe for a person to touch the metal case, even if the live

wire touches the metal case.

[2 marks]

Mark scheme

Show the mark scheme Mark scheme table for question 05: 05.1: swap the blue wire and the green and yellow wire (1 mark). 05.2: 230 V (1 mark) and 50 Hz (1 mark). 05.3: 0 V (1 mark). 05.4: circuit symbol of a rectangle with a wire passing straight through the middle horizontally (1 mark). 05.5: person could get an electric shock / electrocuted (1 mark) because there is a current in the person / potential difference across the person (1 mark). 05.6: charge flows through the earth wire instead of the person (1 mark) because resistance of the earth wire is much less than that of a person / fuse melts or blows (1 mark). Total = 9 marks.

AO /

Question Answers Extra information Mark

Spec. Ref.

05.1 swap the blue wire and the allow connect the blue wire to 1 AO2

green and yellow wire the neutral pin and the yellow 6.2.3.2

and green wire to the earth pin.

allow swap the earth and neutral

wires

ignore the earth wire and neutral

wire are wrongly connected

05.2 230 (V) 1 AO1

6.2.3.1

50 (Hz) 1 6.2.3.2

05.3 0 (V) 1 AO1

6.2.3.2

05.4 1 AO1

6.2.1.1

05.5 the person could get an electric allow so the person could be 1 AO3

shock electrocuted 6.2.3.2

because there is a current in the allow because the person 1

person provides a connection (from the

washing machine) to earth

allow because there is a

potential difference across the

person

05.6 the charge flows through the 1 AO3

earth wire (instead of the 6.2.3.2

person)

because the resistance of the allow so the case does not 1

earth wire is much less than that become live

14 of a person allow so the fuse will break /

melt / blow

Total 9

How to answer it

Mains Electricity, Plug Wiring & Electrical Safety

WHAT THIS QUESTION TESTS

This question assesses fundamental recall and explanatory skills from AQA GCSE Physics / Combined Science Topic 6.2 (Electricity in the Home):

  • Plug Wiring: Colour-coding and correct terminal positions for three-core cables.
  • UK Mains Supply: Exact standard values for domestic potential difference (voltage) and alternating frequency.
  • Wire Potentials: Comparing operating potential differences of the live, neutral, and earth wires.
  • Circuit Symbols: Drawing standard circuit components (fuse).
  • Safety Mechanisms: Explaining electrical shocks, earthing paths, low-resistance connections, and how fuses protect the user from metal casing faults.
PART 05.1 • 1 MARK

Wiring a Three-Pin Plug

Identifying and correcting wiring errors inside a UK standard plug

✅ Correct Answer

Swap the blue wire and the green-and-yellow wire.

Also accepted: "Connect the blue wire to the neutral pin and the green-and-yellow wire to the earth pin."

Award 1 mark for specifying the exact swap or correct final pin positions.

💡 Key Knowledge

Remember positions using standard mnemonics:

  • B L ue: Goes to the Left (Neutral pin, 0 V).
  • B R own: Goes to the Right (Live pin, 230 V, connected through fuse).
  • Green & Yellow stripes: Goes to the Top (Earth pin, 0 V).

🧠 Exam Technique

The question asks: "What should be done to connect the wires correctly?"

Always give an action (e.g., "swap wire X with wire Y") rather than merely stating that it is wrong.

❌ Common Errors

Merely writing "the earth wire and neutral wire are wrongly connected" receives 0 marks because it repeats the premise rather than describing the fix.

PART 05.2 • 2 MARKS

UK Mains Electricity Supply Specifications

Factual recall of domestic alternating current (a.c.) parameters

✅ Correct Answer

  • The potential difference is 230 V [1 mark]
  • The frequency is 50 Hz [1 mark]

💡 Key Knowledge

UK domestic electricity is an alternating current (a.c.) supply:

  • Current changes direction 50 times per second ( 50 Hz ).
  • Average effective potential difference is 230 V .

❌ Common Errors

  • Confusing UK values with US mains ( 110 V / 60 Hz ).
  • Guessing 240 V or incorrect frequencies like 100 Hz or 230 Hz .
PART 05.3 • 1 MARK

Potential Difference Between Neutral and Earth

Understanding reference potentials in household circuits

✅ Correct Answer

Potential difference = 0 V

Award 1 mark for 0 (or "zero").

💡 Key Knowledge

Both wires reside at ground/earth potential:

  • Earth wire: Connected directly to ground ( 0 V ).
  • Neutral wire: Completes the circuit and is grounded back at the local substation ( ~0 V ).
  • Difference: 0 V - 0 V = 0 V .

🧠 Exam Technique

Do not confuse the potential difference between live and neutral (which is 230 V) with the potential difference between neutral and earth (which is 0 V).

PART 05.4 • 1 MARK

Circuit Symbol for a Fuse

Standard circuit diagram representations

✅ Correct Answer & Symbol Spec

───[───]───
A rectangle with a central connecting wire passing all the way through horizontally.
Award 1 mark for a rectangle with an uninterrupted central straight line running straight through it.

❌ Common Errors

  • Drawing a standard resistor: A rectangle with connecting lines that stop at the outside boundary (wire does not go through).
  • Drawing a thermistor or LDR: Adding diagonal hockey sticks or arrows.
  • Freehand sketches with loose, disjointed gaps in the wire line.
PART 05.5 • 2 MARKS

Appliance Fault Without Earth Wire

Explaining electric shock hazards when touching a live metal casing

✅ Correct Answer (Mark Scheme Breakdown)

Must make two distinct points:

  1. The person could receive an electric shock / be electrocuted. [1 mark]
  2. Because a current flows through the person / the person provides a connection to earth / there is a potential difference across the person. [1 mark]

💡 The Science Behind the Mark

  • The live wire touches the metal casing, raising the casing to 230 V.
  • A person standing on the floor is at 0 V (earth potential).
  • Touching the casing creates a large potential difference ( 230 V ) across the person, driving dangerous current through their body into the ground.

❌ Common Errors

Just stating "the person will be hurt" is too vague for Mark 1 (use "shock" or "electrocuted"). Saying "electricity will jump" without mentioning current flowing through the person misses Mark 2.

🧠 Top Tip

Always connect the consequence (shock) directly to the physics mechanism (potential difference causes a current to pass through the body).

PART 05.6 • 2 MARKS

How the Earth Wire Protects the User

Explaining low-resistance alternative paths and fuse action

✅ Correct Answer (Mark Scheme Breakdown)

  1. The charge / current flows through the earth wire (instead of the person). [1 mark]
  2. Because the resistance of the earth wire is much lower than that of a person. [1 mark]
    Alternative 2nd mark: "so the casing does not become live" OR "causes a large surge that melts/blows the fuse".

💡 Step-by-Step Protection Mechanism

  1. Low Resistance Path: The copper earth wire has a tiny resistance compared to human skin/body resistance.
  2. Current Diverts: Current takes the path of least resistance through the earth wire straight to ground.
  3. Fuse Melts: The very low resistance causes a huge surge in current, which rapidly overheats and melts the fuse, completely isolating the appliance from the 230 V live supply.

🧠 Exam Technique

When comparing pathways, make explicit comparisons using comparative words: "resistance of earth wire is lower / much less than the person".

❌ Common Errors

  • Claiming that the earth wire "absorbs all the electricity" (unscientific phrasing).
  • Stating the fuse "turns off" rather than melts, blows, or breaks the circuit.

Topics

Physics · P2: Electricity

Question and mark scheme from the AQA GCSE Combined Science: Trilogy examination, Physics Paper 1 (Foundation), November 2020. QuestionVault is an independent revision resource; questions remain the copyright of the awarding body.